Problem Overview
We calculate the vertical liquid rise rate dtdh inside a spherical industrial chemical dome of fixed internal radius R=12.0 m receiving liquid hydrocarbon at a constant volumetric inflow rate of dtdV=15.0 m3/min. The liquid volume is governed by the spherical cap relation:
V(h)=πRh2−31πh3
Step-by-Step Mathematical Solution
Step 1: Differentiate the Spherical Cap Relation with Respect to Time
The governing formula is the Spherical Cap Volume Relation:
V=πRh2−31πh3
(This formula and its time derivative principles are defined in Related Rates.)
Here, the tank radius R=12.0 m is a static constant (dtdR=0), so we substitute R=12 before differentiation:
V=12πh2−31πh3
Differentiating both sides implicitly with respect to time t using the Power Rule and Chain Rule:
dtdV=dtd[12πh2−31πh3]=(24πh−πh2)dtdh=πh(24−h)dtdh
Isolating the vertical rise rate dtdh:
dtdh=πh(24−h)dtdV
Step 2: Compute Rise Rate at Depth h=4.0 m
Substitute dtdV=15.0 m3/min and h=4.0 m:
dtdh=π(4.0)(24−4.0)15.0=π(4.0)(20.0)15.0=80.0π15.0=16π3 m/min≈0.05968 m/min
Converting to centimeters per minute:
dtdh≈5.97 cm/min
Step 3: Comparative Analysis at h=2.0 m and h=12.0 m
- At shallow depth h=2.0 m:
dtdh=π(2.0)(24−2.0)15.0=44.0π15.0=44π15 m/min≈0.1085 m/min≈10.85 cm/min
- At mid-depth (equator) h=12.0 m:
dtdh=π(12.0)(24−12.0)15.0=144.0π15.0=48π5 m/min≈0.03316 m/min≈3.32 cm/min
Engineering Conclusion
In chemical process engineering and industrial storage management, the cross-sectional area of a spherical vessel varies drastically with height (Across(h)=π(2Rh−h2)=πh(24−h)). Notice that:
dtdV=Across(h)⋅dtdh⟹dtdh=Across(h)1dtdV
At the base of the tank (h=2 m), the horizontal surface area is small (44π m2), causing the fluid level to surge rapidly upward at 10.85 cm/min. At the equator (h=12 m), the cross-section reaches its maximum area (144π m2), slowing the rise rate to just 3.32 cm/min.
Automated tank telemetry uses this related rates model to dynamically predict ullage compression (the compression of volatile gas headspace above the liquid). If liquid rises too quickly near the top of the vessel, the rapid reduction in vapor volume can exceed the mass flow capacity of the overhead pressure relief valves, triggering emergency flaring. By predicting dtdh, digital control systems automatically modulate feed pumps to throttle charging rates as liquid depth approaches tank capacity.