🌱 Tony's Memex Tony's Intertwingled Memex
Digital Garden | OER Curriculum
Home / Digital Garden / Chemical Bioreactor Dissolved Oxygen Depletion (Chemical & Environmental Engineering) Solution

Chemical Bioreactor Dissolved Oxygen Depletion (Chemical & Environmental Engineering) Solution

Problem Overview

We evaluate the dynamic dissolved oxygen profile C(t)=8tt2+4C(t) = \frac{8t}{t^2 + 4} (mg/L\text{mg/L}) for t≥0t \ge 0. We compute dCdt\frac{dC}{dt}, construct a sign chart, apply the First Derivative Test and Single Critical Point Rule to find the global peak oxygen level, and assess aeration turbine controls.


Step-by-Step Mathematical Solution

Step 1: Differentiate via the Quotient Rule

The governing formulation is the Quotient Rule:

ddt[u(t)v(t)]=u′(t)v(t)−u(t)v′(t)[v(t)]2\frac{d}{dt}\left[\frac{u(t)}{v(t)}\right] = \frac{u'(t)v(t) - u(t)v'(t)}{[v(t)]^2}
(This rule is defined in Differentiation Rules - Basics, Powers, Products and Quotients.)

  1. Define numerator and denominator:
    u(t)=8t  ⟹  u′(t)=8u(t) = 8t \implies u'(t) = 8
    v(t)=t2+4  ⟹  v′(t)=2tv(t) = t^2 + 4 \implies v'(t) = 2t
  2. Substitute into the Quotient Rule:
    C′(t)=8(t2+4)−8t(2t)(t2+4)2=8t2+32−16t2(t2+4)2=32−8t2(t2+4)2C'(t) = \frac{8(t^2 + 4) - 8t(2t)}{(t^2 + 4)^2} = \frac{8t^2 + 32 - 16t^2}{(t^2 + 4)^2} = \frac{32 - 8t^2}{(t^2 + 4)^2}
  3. Factor the numerator:
    C′(t)=8(4−t2)(t2+4)2=8(2−t)(2+t)(t2+4)2C'(t) = \frac{8(4 - t^2)}{(t^2 + 4)^2} = \frac{8(2 - t)(2 + t)}{(t^2 + 4)^2}

Step 2: Locate and Filter Critical Numbers

The governing concept is Critical Numbers:

C′(t)=0orC′(t) does not existC'(t) = 0 \quad \text{or} \quad C'(t) \text{ does not exist}
(This concept is defined in Critical Numbers and Critical Points.)

  1. Stationary Points (C′(t)=0C'(t) = 0): Set the factored numerator to zero:
    8(2−t)(2+t)=0  ⟹  t=2ort=−28(2 - t)(2 + t) = 0 \implies t = 2 \quad \text{or} \quad t = -2
  2. Domain Filter: The physical operational domain is t∈[0,∞)t \in [0, \infty). Therefore, t=−2t = -2 is discarded.
  3. Singular Points (C′(t) DNEC'(t) \text{ DNE}): The denominator is (t2+4)2(t^2 + 4)^2. Because t2+4≥4>0t^2 + 4 \ge 4 > 0 for all real tt, the denominator is never zero. There are no singular points.
  4. Valid Critical Number: The function has exactly one critical number in its domain:
    t=2 hourst = 2\text{ hours}

Step 3: Construct Sign Chart & Apply First Derivative Test

Evaluate the sign of C′(t)=8(2−t)(2+t)(t2+4)2C'(t) = \frac{8(2 - t)(2 + t)}{(t^2 + 4)^2} on [0,∞)[0, \infty) around t=2t = 2:

  • Note that the denominator (t2+4)2>0(t^2 + 4)^2 > 0 and the factor (2+t)>0(2 + t) > 0 for all t>0t > 0. The sign is controlled strictly by (2−t)(2 - t).
  • Interval (0,2)(0, 2): Test t=1  ⟹  C′(1)=8(1)(3)(1+4)2=2425>0  ⟹  (+)t = 1 \implies C'(1) = \frac{8(1)(3)}{(1 + 4)^2} = \frac{24}{25} > 0 \implies (+). Concentration is increasing (↗\nearrow).
  • Interval (2,∞)(2, \infty): Test t=3  ⟹  C′(3)=8(−1)(5)(9+4)2=−40169<0  ⟹  (−)t = 3 \implies C'(3) = \frac{8(-1)(5)}{(9 + 4)^2} = -\frac{40}{169} < 0 \implies (-). Concentration is decreasing (↘\searrow).

Extremum Classification:

  • Because C′(t)C'(t) transitions from positive to negative (+→−+ \to -) at t=2t = 2, C(2)C(2) is a local maximum.
  • By the Single Critical Point Rule on [0,∞)[0, \infty), because t=2t = 2 is the only interior critical number and C(0)=0C(0) = 0, C(2)C(2) is guaranteed to be the absolute maximum over the entire domain:
    C(2)=8(2)(2)2+4=164+4=168=2.0 mg/LC(2) = \frac{8(2)}{(2)^2 + 4} = \frac{16}{4 + 4} = \frac{16}{8} = 2.0\text{ mg/L}
  • Absolute Maximum Value: 2.0 mg/L2.0\text{ mg/L} at location t=2 hourst = 2\text{ hours}.

Step 4: Asymptotic Behavior & Operational Control

  1. Long-Term Limit: Evaluate the limit as t→∞t \to \infty:
    lim⁡t→∞C(t)=lim⁡t→∞8tt2+4=lim⁡t→∞8/t1+4/t2=01=0 mg/L\lim_{t \to \infty} C(t) = \lim_{t \to \infty} \frac{8t}{t^2 + 4} = \lim_{t \to \infty} \frac{8/t}{1 + 4/t^2} = \frac{0}{1} = 0\text{ mg/L}
  2. Process Engineering Control Decision: After the initial aeration surge reaches peak saturation (2.0 mg/L2.0\text{ mg/L}) at t=2 hourst = 2\text{ hours}, active biological consumption drives the dissolved oxygen steadily downward toward zero. Environmental protection regulations require a minimum DO concentration of Cmin⁡≥1.0 mg/LC_{\min} \ge 1.0\text{ mg/L} to prevent microbial die-off. Setting C(t)=1.0  ⟹  8tt2+4=1  ⟹  t2−8t+4=0  ⟹  t=4±23≈7.46 hoursC(t) = 1.0 \implies \frac{8t}{t^2 + 4} = 1 \implies t^2 - 8t + 4 = 0 \implies t = 4 \pm 2\sqrt{3} \approx 7.46\text{ hours}. Thus, the supervisory SCADA control system must automatically restart auxiliary air compressors before t≈7.46 hourst \approx 7.46\text{ hours}.