Problem Overview
We calculate the slope ΞΈ ( x ) = d y d x \theta(x) = \frac{dy}{dx} ΞΈ ( x ) = d x d y β and mid-span tangent line equation for an engineered structural steel cantilever beam governed by the fourth-order elastic deflection equation:
y ( x ) = w 0 24 E I ( x 4 β 4 L x 3 + 6 L 2 x 2 ) y(x) = \frac{w_0}{24EI}\left(x^4 - 4Lx^3 + 6L^2x^2\right) y ( x ) = 24 E I w 0 β β ( x 4 β 4 L x 3 + 6 L 2 x 2 )
over the domain 0 β€ x β€ L 0 \le x \le L 0 β€ x β€ L , where C = w 0 24 E I C = \frac{w_0}{24EI} C = 24 E I w 0 β β is the constant flexural rigidity scaling coefficient and L = 6.0 Β m L = 6.0\text{ m} L = 6.0 Β m .
Step-by-Step Mathematical Solution
Step 1: Compute the First Derivative d y d x \frac{dy}{dx} d x d y β
The governing mathematical rules are the Constant Multiple Rule and Power Rule :
d d x [ c β
f ( x ) ] = c β
f β² ( x ) , d d x [ x n ] = n x n β 1 \frac{d}{dx}[c \cdot f(x)] = c \cdot f'(x), \qquad \frac{d}{dx}[x^n] = n x^{n-1} d x d β [ c β
f ( x )] = c β
f β² ( x ) , d x d β [ x n ] = n x n β 1
(These rules are defined in Power Rule .)
Treating C = w 0 24 E I C = \frac{w_0}{24EI} C = 24 E I w 0 β β and L L L as constants, differentiate y ( x ) y(x) y ( x ) term-by-term with respect to x x x :
ΞΈ ( x ) = d y d x = C β
d d x [ x 4 β 4 L x 3 + 6 L 2 x 2 ] \theta(x) = \frac{dy}{dx} = C \cdot \frac{d}{dx}\left[x^4 - 4Lx^3 + 6L^2x^2\right] ΞΈ ( x ) = d x d y β = C β
d x d β [ x 4 β 4 L x 3 + 6 L 2 x 2 ]
d y d x = C β
[ 4 x 3 β 4 L ( 3 x 2 ) + 6 L 2 ( 2 x ) ] \frac{dy}{dx} = C \cdot \left[4x^3 - 4L(3x^2) + 6L^2(2x)\right] d x d y β = C β
[ 4 x 3 β 4 L ( 3 x 2 ) + 6 L 2 ( 2 x ) ]
d y d x = C β
[ 4 x 3 β 12 L x 2 + 12 L 2 x ] = 4 C x ( x 2 β 3 L x + 3 L 2 ) \frac{dy}{dx} = C \cdot \left[4x^3 - 12Lx^2 + 12L^2x\right] = 4Cx\left(x^2 - 3Lx + 3L^2\right) d x d y β = C β
[ 4 x 3 β 12 L x 2 + 12 L 2 x ] = 4 C x ( x 2 β 3 Lx + 3 L 2 )
Substituting back C = w 0 24 E I C = \frac{w_0}{24EI} C = 24 E I w 0 β β :
ΞΈ ( x ) = w 0 6 E I ( x 3 β 3 L x 2 + 3 L 2 x ) \theta(x) = \frac{w_0}{6EI}\left(x^3 - 3Lx^2 + 3L^2x\right) ΞΈ ( x ) = 6 E I w 0 β β ( x 3 β 3 L x 2 + 3 L 2 x )
Step 2: Evaluate Boundary Slopes at Support (x = 0 x = 0 x = 0 ) and Tip (x = L x = L x = L )
At the Wall Support (x = 0 x = 0 x = 0 ):
ΞΈ ( 0 ) = w 0 6 E I ( 0 3 β 3 L ( 0 ) 2 + 3 L 2 ( 0 ) ) = 0 \theta(0) = \frac{w_0}{6EI}\left(0^3 - 3L(0)^2 + 3L^2(0)\right) = 0 ΞΈ ( 0 ) = 6 E I w 0 β β ( 0 3 β 3 L ( 0 ) 2 + 3 L 2 ( 0 ) ) = 0
This rigorously confirms the structural boundary condition for a rigid clamp: zero slope at the fixed root.
At the Free Cantilever Tip (x = L x = L x = L ):
ΞΈ ( L ) = w 0 6 E I ( L 3 β 3 L ( L 2 ) + 3 L 2 ( L ) ) = w 0 6 E I ( L 3 β 3 L 3 + 3 L 3 ) = w 0 L 3 6 E I \theta(L) = \frac{w_0}{6EI}\left(L^3 - 3L(L^2) + 3L^2(L)\right) = \frac{w_0}{6EI}\left(L^3 - 3L^3 + 3L^3\right) = \frac{w_0 L^3}{6EI} ΞΈ ( L ) = 6 E I w 0 β β ( L 3 β 3 L ( L 2 ) + 3 L 2 ( L ) ) = 6 E I w 0 β β ( L 3 β 3 L 3 + 3 L 3 ) = 6 E I w 0 β L 3 β
This is the classical structural engineering formula for the maximum tip rotation of a cantilever beam under uniform load.
Step 3: Formulate the Tangent Line at Mid-Span (x = L / 2 = 3.0 Β m x = L/2 = 3.0\text{ m} x = L /2 = 3.0 Β m )
The governing formula is the Point-Slope Equation of a Tangent Line :
y β y 1 = m ( x β x 1 ) , whereΒ m = d y d x β£ x 1 y - y_1 = m(x - x_1), \qquad \text{where } m = \left.\frac{dy}{dx}\right|_{x_1} y β y 1 β = m ( x β x 1 β ) , whereΒ m = d x d y β β x 1 β β
(This formula is defined in Definition of the Derivative .)
Evaluate the deflection height y 1 y_1 y 1 β at x 1 = L / 2 x_1 = L/2 x 1 β = L /2 :
y ( L / 2 ) = C [ ( L 2 ) 4 β 4 L ( L 2 ) 3 + 6 L 2 ( L 2 ) 2 ] y(L/2) = C \left[\left(\frac{L}{2}\right)^4 - 4L\left(\frac{L}{2}\right)^3 + 6L^2\left(\frac{L}{2}\right)^2\right] y ( L /2 ) = C [ ( 2 L β ) 4 β 4 L ( 2 L β ) 3 + 6 L 2 ( 2 L β ) 2 ]
y ( L / 2 ) = C [ L 4 16 β 4 L ( L 3 8 ) + 6 L 2 ( L 2 4 ) ] = C L 4 [ 1 16 β 1 2 + 3 2 ] = C L 4 [ 1 16 + 1 ] = 17 16 C L 4 y(L/2) = C \left[\frac{L^4}{16} - 4L\left(\frac{L^3}{8}\right) + 6L^2\left(\frac{L^2}{4}\right)\right] = C L^4 \left[\frac{1}{16} - \frac{1}{2} + \frac{3}{2}\right] = C L^4 \left[\frac{1}{16} + 1\right] = \frac{17}{16} C L^4 y ( L /2 ) = C [ 16 L 4 β β 4 L ( 8 L 3 β ) + 6 L 2 ( 4 L 2 β ) ] = C L 4 [ 16 1 β β 2 1 β + 2 3 β ] = C L 4 [ 16 1 β + 1 ] = 16 17 β C L 4
Evaluate the tangent slope m m m at x 1 = L / 2 x_1 = L/2 x 1 β = L /2 :
m = ΞΈ ( L / 2 ) = C [ 4 ( L 2 ) 3 β 12 L ( L 2 ) 2 + 12 L 2 ( L 2 ) ] m = \theta(L/2) = C \left[4\left(\frac{L}{2}\right)^3 - 12L\left(\frac{L}{2}\right)^2 + 12L^2\left(\frac{L}{2}\right)\right] m = ΞΈ ( L /2 ) = C [ 4 ( 2 L β ) 3 β 12 L ( 2 L β ) 2 + 12 L 2 ( 2 L β ) ]
m = C [ 4 ( L 3 8 ) β 12 L ( L 2 4 ) + 6 L 3 ] = C L 3 [ 1 2 β 3 + 6 ] = 7 2 C L 3 m = C \left[4\left(\frac{L^3}{8}\right) - 12L\left(\frac{L^2}{4}\right) + 6L^3\right] = C L^3 \left[\frac{1}{2} - 3 + 6\right] = \frac{7}{2} C L^3 m = C [ 4 ( 8 L 3 β ) β 12 L ( 4 L 2 β ) + 6 L 3 ] = C L 3 [ 2 1 β β 3 + 6 ] = 2 7 β C L 3
Write the Tangent Line Equation:
y β 17 16 C L 4 = 7 2 C L 3 ( x β L 2 ) y - \frac{17}{16} C L^4 = \frac{7}{2} C L^3 \left(x - \frac{L}{2}\right) y β 16 17 β C L 4 = 2 7 β C L 3 ( x β 2 L β )
For L = 6.0 Β m L = 6.0\text{ m} L = 6.0 Β m :
L 3 = 216 L^3 = 216 L 3 = 216 , L 4 = 1296 L^4 = 1296 L 4 = 1296 .
y 1 = 17 16 C ( 1296 ) = 1377 C y_1 = \frac{17}{16} C (1296) = 1377 C y 1 β = 16 17 β C ( 1296 ) = 1377 C .
m = 7 2 C ( 216 ) = 756 C m = \frac{7}{2} C (216) = 756 C m = 2 7 β C ( 216 ) = 756 C .
y β 1377 C = 756 C ( x β 3 ) β
β βΉ β
β y = 756 C x β 891 C y - 1377 C = 756 C (x - 3) \implies y = 756 C x - 891 C y β 1377 C = 756 C ( x β 3 ) βΉ y = 756 C x β 891 C
Engineering Conclusion
In structural civil engineering, computing the instantaneous slope d y d x \frac{dy}{dx} d x d y β is just as critical as computing total vertical displacement. When building multi-story cantilever decks, architectural facade glazing (such as floor-to-ceiling glass curtain walls) attaches directly to cantilever floor slabs. While the slab may safely withstand vertical bending stress, excessive rotational slope ΞΈ ( x ) \theta(x) ΞΈ ( x ) imparts destructive in-plane racking and shear strain onto the rigid glass framing. By formulating tangent line equations, structural engineers evaluate the angular clearance envelopes at mid-span and tip connections, ensuring rubber expansion gaskets and slotted slip-joints absorb beam rotation without shattering architectural glass.